October 23, 2026
Filtering Inside a Humanoid Robot Joint: Where the Feedthrough Capacitor Goes
A humanoid robot joint module puts a switching inverter and a microvolt-level encoder inside one aluminium housing the size of a coffee cup. That single fact is what makes filtering a joint different from filtering a cabinet, and it is why the feedthrough capacitor in a joint is not an accessory bolted next to a connector. In most joint designs it is the wall the cable passes through.
The 48 V joint architecture that now dominates humanoid designs made this worse before it made it better. Lower bus voltage allows faster switching devices, and GaN parts switch at fifty to a hundred and fifty volts per nanosecond where the silicon MOSFETs they replace managed ten to twenty. Faster edges mean more energy above a hundred megahertz, in the same band where an encoder’s differential pair is least able to reject it.
Why the Inverter and the Encoder Cannot Be Separated
In a servo cabinet, the drive sits in one enclosure and the motor in another, connected by a shielded cable. The two are metres apart and the cable shield does most of the work. A joint module collapses that distance to a few centimetres because the motor, the inverter, the encoder and the controller all have to fit inside the rotating structure.
The consequence is that the shield no longer has anywhere to end. A cable shield works by carrying common-mode current back to its source, and in a cabinet that source is the drive chassis. In a joint the source is the same housing the encoder reads from, so current returning on the shield passes through the same metal that the encoder signal is referenced to.
Published joint reference designs from the major semiconductor vendors show the same layout answer: current loop at eight to thirty-two kilohertz sampling, PWM carrier anywhere from twenty to eighty, and everything on one board. The faster carrier exists precisely to shrink the DC-link capacitor. It also moves the switching harmonics into the band where a joint’s own wiring resonates.
The Number That Decides the Filter
Common-mode current is displacement current through parasitic capacitance, and it is worth calculating before choosing any part.
Icm = Cpar × dv/dt
Take a small servo motor with about 200 pF from winding to frame, driven by a GaN stage at 50 V/ns. That gives 10 A of displacement current for the duration of the edge. The edge itself lasts 48 V divided by 50 V/ns, just under a nanosecond. A one-nanosecond edge carries meaningful energy to roughly 350 MHz, which is well past the point where a ferrite bead stops behaving like a bead.
Ten amps is not a number a signal-line filter removes. It is a number that has to be given a short, low-inductance path home, and the shortest path available inside a joint is straight out through the housing wall.
Why the Connector Is the Wrong Place
The instinctive fix is to put a filter at the connector where the encoder cable leaves the module. That fails for a reason that is structural rather than electrical: the connector is inside the shield boundary, so the noise has already crossed the boundary before it reaches the filter.
Everything that happens inside the housing happens in a closed metal box, and a closed box is a good place for fields to stay. The problem is the cable. Once the encoder pair leaves through a connector, any common-mode current present on that pair at the connector pin travels the length of the cable and radiates from it. Filtering after the exit point means filtering the current that already left.
A feedthrough capacitor changes this by making the wall the filter. The threaded body screws into the housing and becomes the ground path itself, and the conductor passes through the dielectric with no lead length between the capacitance and the chassis. There is nothing left to filter after the boundary because the boundary is the component.
This is the same argument that governs small cell radios, where the feedthrough mounts in the enclosure wall rather than on the PCB. The selection logic for small cell interfaces and the logic for a joint share that principle, though almost nothing else.
Choosing Capacitance by Self-Resonance, Not by Size
A feedthrough capacitor is a capacitor with a very small inductance in series, and above its self-resonant frequency it stops being a capacitor at all. The resonant point is set by the two together:
f0 = 1 / (2π√(Ls × C))
With a series inductance around 1 nH, which is the right order for a threaded body of this construction, the numbers come out like this:
| Capacitance | Self-resonance at 1 nH | Insertion loss at 100 MHz | Best suited to |
|---|---|---|---|
| 5 pF | about 2.25 GHz | under 1 dB | High-speed pairs that cannot tolerate loading |
| 1000 pF | about 159 MHz | 28 dB | Encoder lines, 3.2 MHz of signal bandwidth |
| 2200 pF | about 107 MHz | 48 dB | Encoder lines, 1.4 MHz of signal bandwidth |
| 0.01 µF | about 50 MHz | 35 dB | Auxiliary DC feeds, not signal lines |
| 0.1 µF | about 16 MHz | 32 dB | Low-frequency bypass, not RF |
The insertion-loss figures assume a 50 Ω system and follow from I = 20 log(1 + Z0 / 2Xc). There is a peak in that column and it does not sit where intuition puts it. At 100 MHz the optimum is about 2500 pF, where the reactance passes through zero on its way from capacitive to inductive and the attenuation reaches 48 dB. A 1000 pF part gives 28 dB at the same frequency. Past the peak the curve turns around: 0.01 µF gives 35 dB and 0.1 µF gives 32 dB, both worse than the 2200 pF part despite carrying five and fifty times the capacitance.
That is the trap in specifying by capacitance. Above self-resonance the part is an inductor, and adding capacitance only moves the resonance further down the band, leaving the noise sitting on the inductive slope where nothing but the series inductance limits impedance.
The obvious conclusion, buy the 2200 pF and get 48 dB, runs into the other half of the problem. A capacitor across a signal pair is also a low-pass filter, and the corner it imposes is set by the source impedance:
fc = 1 / (2π × Zs × C)
Against a 50 Ω source, 1000 pF puts the corner at 3.2 MHz and 2200 pF pulls it down to 1.4 MHz. An encoder running a 4 MHz data rate needs its harmonics intact well above that, and a joint that has been told it has 1.4 MHz of bandwidth will round off edges until the position loop does not close. This is why the answer for an encoder line is usually 1000 pF rather than the value that measures best on a network analyser: 28 dB at 100 MHz with 3.2 MHz of bandwidth is a working encoder, and 48 dB with 1.4 MHz is a broken one.
Both of those parts are standard 7 A C-type bodies in the Xuansn threaded range, the 1000 pF 100 V part and the 2200 pF version, so the choice between them costs nothing but a line on the drawing.
Seven Amps Is a Signal Rating, Not a Power Rating
Threaded feedthrough capacitors in this class carry a rated current around 7 A, and that number gets misread as permission to run a motor phase through one.
Do the arithmetic for a joint. A 500 W joint on a 48 V bus draws about 10.4 A of average current, and peak current during acceleration is higher still. A 7 A feedthrough cannot carry that, and no amount of filtering benefit justifies running it at 150% of rating in a part that has to survive a decade of thermal cycling inside a moving limb.
The correct division is straightforward. Phase conductors leave through a sealed bulkhead or a shielded gland sized for the current. Everything signal-level, meaning the encoder pair, the Hall lines, the temperature sensor and any auxiliary supply, goes through feedthrough capacitors. That is also the division that puts the filtering where the vulnerable circuitry is rather than where the power is.
Dielectric Choice Changes With Temperature and Bias
The capacitance printed on the part is measured at 25 °C and low bias. A joint spends its life at whatever temperature the motor reaches after an hour of walking, and Class II dielectrics move under both heat and applied voltage.
Xuansn’s threaded range shows the spread across the same 7 A, C-type construction. The 5 pF part uses NPO, which holds its value across temperature and bias because it is a Class I dielectric. The 1000 pF part uses X5R, the 3300 pF and 0.1 µF parts use X7R, and the 2200 pF and 0.01 µF parts use Y5U and Y5V respectively. A Y5V part at its upper temperature limit can lose a large fraction of its nominal capacitance, which matters when the whole design margin was calculated from the nominal number.
For a joint, X7R is the usual compromise. It holds capacitance to 125 °C where X5R stops at 85 °C, and a joint housing that has been driving for an hour will exceed 85 °C. Where the attenuation budget is tight and the capacitance value is small, NPO removes the question entirely.
What Belongs on the Drawing
A feedthrough capacitor is a mechanical part as much as an electrical one, and the specification has to say so.
| Item | Why it has to be stated |
|---|---|
| Thread size and pitch | Sets both the panel hole and the contact area carrying the return current |
| Mounting torque | Too little leaves a high-impedance joint; too much cracks the ceramic |
| Plating layer | Silver and nickel behave differently against anodised or painted housing walls |
| Panel treatment | Anodising is an insulator; the thread needs bare metal contact or the ground path is lost |
| Rated current per line | Confirms the part is carrying signals, not motor current |
The plating question is the one that most often goes wrong in practice. The same product family appears with silver and with nickel plating, and a joint housing that has been anodised for corrosion resistance will present an insulating layer to whichever one is chosen. The thread has to be masked and left bare, or the capacitor has a dielectric on both sides and one of them is not the one you specified.
The rest of the mounting decision follows from the comparison of threaded, solder-in and press-in bodies: threaded is the only one of the three that can be assembled and replaced from outside a sealed housing.
What Comes Next
This is the first piece in a short series on filtering inside robot joints. The next one works through the cable side of the same problem, which is what happens to the shield after it leaves the feedthrough and why a shield grounded at both ends behaves differently in a moving limb than in a fixed cabinet.
Questions About Filtering Robot Joints
Can a ferrite bead replace a feedthrough capacitor in a joint?
Not for the common-mode path. A ferrite bead is a series impedance and it needs a return path to work against; the whole difficulty in a joint is that the return path and the signal reference are the same housing metal. A feedthrough capacitor provides that return path at the wall. The two are complementary rather than alternatives, and many designs use both.
How many feedthrough capacitors does a joint module need?
One per line that crosses the wall, which for a typical joint means the encoder pair, the Hall sensors and any auxiliary supply. Sharing a feedthrough between lines defeats the purpose, because the common-mode current from one line can then couple onto the others through the shared conductor.
Does a faster PWM carrier make joint EMI better or worse?
Both, and it depends on which part you measure. Raising the carrier from 20 kHz to 80 kHz can let the DC-link capacitor shrink and moves the switching fundamental up, but the harmonic energy from the edges is set by dv/dt rather than by carrier frequency. A GaN stage at 50 V/ns radiates the same edge energy whether it repeats at 20 kHz or 80 kHz, and repeats it four times as often.
What insertion loss should I specify for an encoder line?
Enough to cover the band where the edge energy sits, not enough to load the pair. For a 1000 pF part that means 28 dB at 100 MHz, and the specification should state the measurement system because insertion loss is meaningless without it. A number quoted without the source and load impedance cannot be compared between suppliers.
Working on a joint module and need a feedthrough that fits the wall? Send Xuansn the panel thickness, thread size, the lines crossing the wall and the capacitance you have budgeted, and our engineers will come back with a threaded body, a dielectric class for your housing temperature and the torque figure to put on the drawing. Reach us at coco@xuanxcapacitors.com, call +86-769-8166 8821, or send your specification through the contact page.